Optimized stamp impression without an adhesive fillet on the quartz sidewall.
How does Microdul support customers with technical challenges? Here’s a case where our engineering team proactively solved a tough problem before it could have turned into a costly recall. Interestingly, during troubleshooting, the AI was far off the mark—the quality of the electronic module was ensured by human expertise.
This involves the smart electronics of a ladies’ watch. “Swiss Made” promises reliability and durability—top priorities for the manufacturer. The ultra-low-power circuit we manufactured contains an ASIC and a quartz crystal as the clock source.
The slim case required a miniaturized electronic module. The quartz is mounted onto the PCB with an accuracy of ±20 micrometers. If the positioning weren’t so precise, it would collide with the watch case back.
During the calibration of the first production run, it was discovered that a few modules were consuming too much power. But what was the cause: the chip? The quartz? The wire bonds? The adhesive bond?
The troubleshooting was difficult: The wire bonds were fine, the chip was working, and the quartz was oscillating. But after a few tests, it became clear: the problem must lie in the connection between the quartz and the PCBA. Since the quartz is only 1.6 x 1 mm in size and less than 0.5 mm high, the contacts underneath are inaccessible, and the adhesive bond is thinner than a hair, it was impossible to detect the fault even under a microscope or to test the connections with a multimeter.
By grinding down the adhesive menisci, one quartz was restored to working order. This meant there must have been a short circuit or leakage current along the quartz’s side wall—which is supposed to be insulating—causing power to dissipate when contact was minimal and causing the circuit to fail when contact was significant.
This was followed by a chemical element analysis: Using laser-induced plasma spectroscopy (LIPS), a very small molybdenum spot was detected on the quartz, which became visible under the digital microscope with the correct polarization.
According to the manufacturer, this is a thin strip of molybdenum that holds the quartz in place during production (before the housing is formed around it) and extends to the outer surface. The problem: Molybdenum is conductive. This does not interfere with the conventional use of the quartz as a soldered SMD component, but as an integrated component—precisely positioned using conductive adhesive—the spot creates an artifact that could potentially render the watch circuit inoperable.
Microdul analyzed, adjusted, and re-qualified the bonding process in collaboration with the customer. The application now uses an optimized stamp pattern—instead of a single stamp per pad—with no adhesive fillet on the quartz sidewall. This results in a smaller wetted area that remains at a safe distance from the artifact. Shear tests ensure the quality of the new bond.
How did the customer benefit? Microdul stopped production, informed the customer, and set out to investigate the cause. Our team ensured that no long-term problems would arise due to age-related wear and tear. The customer received a solution with low ongoing costs—and greatly appreciated it!
Molybdenum artifact next to the adhesive fillet on the side wall of the quartz.
Comparison of old (bottom) and new stamp image (top).